Nanolab 500 Clinical Chemistry Analyzer

Brand: Trivitron

Compare

Description

FEATURES

  • Up to 300 photometric tests/hr or up to 480 tests/hour with optional ISE module
  • Continuous sample loading – easy accessibility to the sample sectors without the need to open the analyzer
  • Intelligent operating software with automatic reflexing testing, QC scheduling and automatic method calibration.
  • 72 Positions reagent tray with onboard cooling and Internal Barcode scanner
  • 95 positions sample tray with internal barcode scanner.
  • Clot detection and probe collision prevention system for safe and reliable operation.

TECHNICAL SPECIFICATIONS

THROUGHPUT

Up to 300 photometric tests/hr or up to 480 tests/hour with optional ISE module

SAMPLES AND REAGENT

Samples

  • Sample volume: 2 to 100 μl/test (in increments of 1 μl).
  • Sample tray: 95 (5 racks x 19 positions).
  • Primary tube (length up to 100 mm)
  • Pediatric vial

Reagents

  • Reagent tray: up to 72 single reagents
  • Multiple vials per test
  • Refrigerated compartment at 8 °C ± 1 °C

SAMPLES AND REAGENT HANDLING

  • Pipetting Arm:One pipetting arm for sample and reagent, including reaction preheater, probe collision sensor, capacitive level sensor and reaction mixer.
  • Probe cleaning : Internal and external

REACTION

  • Water consumption : 1.5 l / hour (deionized)
  • Reaction cuvette: 80 re-usable plastic cuvettes.Optical length: 6 mm
  • Reaction volume: 180-500 μl
  • Warm air incubator: 37 °C
  • Reaction time :  0 to 10 min.
  • Washing station: 6 stages

OPTICAL SYSTEM

  • Light source: Precision UV quartz halogen lamp
  • Photometric range: -0.1 to 3 A
  • Measuring wavelength: 340, 380, 405, 450, 490, 505, 550, 590, 620, 650, 700, 750 nm
  • Photometry:  single or double-wavelength simultaneous reading

ANALYTICAL MODES

  • Full random access or batch mode operation with STAT sample priority function
  • Multiple methodology options- End point, Kinetic, Coagulation, Calculated, Turbidimetry, enzymes and Drugs of Abuse.
  • Choice of calibration options- Linear, Multilinear, Sigmoid, Logit-log ( 4 & 5 point) & spline
  • Automatic sample dilution and reflex testing

QUALITY CONTROL

  • Levy-Jennings, Twin plots & Westgard rules

DATA MANAGEMENT

  • Bidirectional LIS interface, RS-232C, ASTM E1381

ISE

  • Module: MEDICA ISE module
  • Electrodes: Li+, Na+, K+, Cl
  • Sample types: Serum and Urine

WORKING CONDITIONS

  • Power Requirements: 110/230 VAC, 50/60Hz, 550 VA
  • Working Temperature: 18 – 30 °C
  • Humidity: 35-80 %

DIMENSIONS

  • Size (Width x Depth x Height) 91 cm x 68 cm x 65 cm 36.4 in x 27.2 in x 26 in
  • Weight: 110 kg; 242 lbs

PC REQUIREMENTS

Windows™ 8 computer, 4 Gbytes RAM, 500 Gbytes HDD, DVD-ROM drive, min. 1024×768 resolution SVGA, 15” or bigger monitor, keyboard, mouse, USB ports for link with the analyzer, 1 RS-232 port or 1 USB/RS-232 converter for  link with the LIS, USB port for printer

BENEFITS

Continuous sample loading – easily accessibility to the sample sectors without the need to open the analyzer

Barcode reading of samples and reagents

Intelligent operating software with automatic reexing testing, QC scheduling and automatic method calibration.

Clot detection and probe collision prevention system for safe and reliable operation.

The new Nanolab 500 shares similar software and components with the Nanolab 700 analyzer. (e.g. sample tray reagent & reaction trays, pipetting  arm, photometer, barcode reader, clot detection system and dilution logic). All of which enables easier service and simplied maintenance of spare parts inventory stock.