{"id":20472,"date":"2023-03-26T08:49:31","date_gmt":"2023-03-26T08:49:31","guid":{"rendered":"https:\/\/nestcorner.com\/?post_type=product&#038;p=20472"},"modified":"2023-03-26T08:49:31","modified_gmt":"2023-03-26T08:49:31","slug":"nanolab-500-clinical-chemistry-analyzer","status":"publish","type":"product","link":"https:\/\/nestcorner.com\/index.php\/product\/nanolab-500-clinical-chemistry-analyzer\/","title":{"rendered":"Nanolab 500 Clinical Chemistry  Analyzer"},"content":{"rendered":"<div class=\"panel-heading active-panel\" data-toggle=\"collapse\" data-parent=\"#accordion-product\" data-target=\"#attributediv_0\" aria-expanded=\"true\">\n<h4 class=\"panel-title \">FEATURES<\/h4>\n<\/div>\n<div id=\"attributediv_0\" class=\"panel-collapse collapse in\" aria-expanded=\"true\">\n<div class=\"panel-body\">\n<ul>\n<li>Up to 300 photometric tests\/hr or up to 480 tests\/hour with optional ISE module<\/li>\n<li>Continuous sample loading \u2013 easy accessibility to the sample sectors without the need to open the analyzer<\/li>\n<li>Intelligent operating software with automatic reflexing testing, QC scheduling and automatic method calibration.<\/li>\n<li>72 Positions reagent tray with onboard cooling and Internal Barcode scanner<\/li>\n<li>95 positions sample tray with internal barcode scanner.<\/li>\n<li>Clot detection and probe collision prevention system for safe and reliable operation.<\/li>\n<\/ul>\n<div class=\"panel-heading active-panel\" data-toggle=\"collapse\" data-parent=\"#accordion-product\" data-target=\"#attributediv_4\" aria-expanded=\"true\">\n<h4 class=\"panel-title \">TECHNICAL SPECIFICATIONS<\/h4>\n<\/div>\n<div id=\"attributediv_4\" class=\"panel-collapse collapse in\" aria-expanded=\"true\">\n<div class=\"panel-body\">\n<p><b>THROUGHPUT<\/b><\/p>\n<p>Up to 300 photometric tests\/hr or up to 480 tests\/hour with optional ISE module<\/p>\n<p><b>SAMPLES AND REAGENT<\/b><\/p>\n<p><i>Samples<\/i><\/p>\n<ul>\n<li><b>Sample volume:<\/b>\u00a02 to 100 \u03bcl\/test (in increments of 1 \u03bcl).<\/li>\n<li><b>Sample tray:<\/b>\u00a095 (5 racks x 19 positions).<\/li>\n<li>Primary tube (length up to 100 mm)<\/li>\n<li>Pediatric vial<\/li>\n<\/ul>\n<p><i>Reagents<\/i><\/p>\n<ul>\n<li><b>Reagent tray<\/b>: up to 72 single reagents<\/li>\n<li>Multiple vials per test<\/li>\n<li>Refrigerated compartment at 8 \u00b0C \u00b1 1 \u00b0C<\/li>\n<\/ul>\n<p><b>SAMPLES AND REAGENT HANDLING<\/b><\/p>\n<ul>\n<li><b>Pipetting Arm<\/b>:One pipetting arm for sample and reagent, including reaction preheater, probe collision sensor, capacitive level sensor and reaction mixer.<\/li>\n<li><b>Probe cleaning<\/b>\u00a0: Internal and external<\/li>\n<\/ul>\n<p><b>REACTION<\/b><\/p>\n<ul>\n<li><b>Water consumption :<\/b>\u00a01.5 l \/ hour (deionized)<\/li>\n<li><b>Reaction cuvette:<\/b>\u00a080 re-usable plastic cuvettes.Optical length: 6 mm<\/li>\n<li><b>Reaction volume:<\/b>\u00a0180-500 \u03bcl<\/li>\n<li><b>Warm air incubator:<\/b>\u00a037 \u00b0C<\/li>\n<li><b>Reaction time :<\/b>\u00a0 0 to 10 min.<\/li>\n<li><b>Washing station:<\/b>\u00a06 stages<\/li>\n<\/ul>\n<p><b>OPTICAL SYSTEM<\/b><\/p>\n<ul>\n<li><b>Light source:<\/b>\u00a0Precision UV quartz halogen lamp<\/li>\n<li><b>Photometric range:<\/b>\u00a0-0.1 to 3 A<\/li>\n<li><b>Measuring wavelength:<\/b>\u00a0340, 380, 405, 450, 490, 505, 550, 590, 620, 650, 700, 750 nm<\/li>\n<li><b>Photometry:<\/b>\u00a0 single or double-wavelength simultaneous reading<\/li>\n<\/ul>\n<p><b>ANALYTICAL MODES<\/b><\/p>\n<ul>\n<li>Full random access or batch mode operation with STAT sample priority function<\/li>\n<li>Multiple methodology options- End point, Kinetic, Coagulation, Calculated, Turbidimetry, enzymes and Drugs of Abuse.<\/li>\n<li>Choice of calibration options- Linear, Multilinear, Sigmoid, Logit-log ( 4 &amp; 5 point) &amp; spline<\/li>\n<li>Automatic sample dilution and reflex testing<\/li>\n<\/ul>\n<p><b>QUALITY CONTROL<\/b><\/p>\n<ul>\n<li>Levy-Jennings, Twin plots &amp; Westgard rules<\/li>\n<\/ul>\n<p><b>DATA MANAGEMENT<\/b><\/p>\n<ul>\n<li>Bidirectional LIS interface, RS-232C, ASTM E1381<\/li>\n<\/ul>\n<p><b>ISE<\/b><\/p>\n<ul>\n<li><b>Module:<\/b>\u00a0MEDICA ISE module<\/li>\n<li><b>Electrodes:\u00a0<\/b>Li+, Na+, K+, Cl<\/li>\n<li><b>Sample types:<\/b>\u00a0Serum and Urine<\/li>\n<\/ul>\n<p><b>WORKING CONDITIONS<\/b><\/p>\n<ul>\n<li><b>Power Requirements:<\/b>\u00a0110\/230 VAC, 50\/60Hz, 550 VA<\/li>\n<li><b>Working Temperature:<\/b>\u00a018 \u2013 30 \u00b0C<\/li>\n<li><b>Humidity:<\/b>\u00a035-80 %<\/li>\n<\/ul>\n<p><b>DIMENSIONS<\/b><\/p>\n<ul>\n<li>Size (Width x Depth x Height) 91 cm x 68 cm x 65 cm 36.4 in x 27.2 in x 26 in<\/li>\n<li><b>Weight:<\/b>\u00a0110 kg; 242 lbs<\/li>\n<\/ul>\n<p><b>PC REQUIREMENTS<\/b><\/p>\n<p>Windows\u2122 8 computer, 4 Gbytes RAM, 500 Gbytes HDD, DVD-ROM drive, min. 1024&#215;768 resolution SVGA, 15\u201d or bigger monitor, keyboard, mouse, USB ports for link with the analyzer, 1 RS-232 port or 1 USB\/RS-232 converter for\u00a0 link with the LIS, USB port for printer<\/p>\n<div class=\"panel-heading active-panel\" data-toggle=\"collapse\" data-parent=\"#accordion-product\" data-target=\"#attributediv_5\" aria-expanded=\"true\">\n<h4 class=\"panel-title \">BENEFITS<\/h4>\n<\/div>\n<div id=\"attributediv_5\" class=\"panel-collapse collapse in\" aria-expanded=\"true\">\n<div class=\"panel-body\">\n<p><b>Continuous sample loading<\/b>\u00a0\u2013 easily accessibility to the sample sectors without the need to open the analyzer<\/p>\n<p><b>Barcode<\/b>\u00a0reading of samples and reagents<\/p>\n<p><b>Intelligent operating software<\/b>\u00a0with automatic re\uf002exing testing, QC scheduling and automatic method calibration.<\/p>\n<p><b>Clot detection<\/b>\u00a0and probe collision prevention system for safe and reliable operation.<\/p>\n<p>The new Nanolab 500 shares\u00a0<b>similar software and components with the Nanolab 700 analyzer<\/b>. (e.g. sample tray reagent &amp; reaction trays, pipetting\u00a0 arm, photometer, barcode reader, clot detection system and dilution logic). All of which enables\u00a0<b>easier service and simpli\uf001ed maintenance<\/b>\u00a0of spare parts inventory stock.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div class=\"panel-heading active-panel\" data-toggle=\"collapse\" data-parent=\"#accordion-product\" data-target=\"#overview-prod\" aria-expanded=\"false\">\n<h4 class=\"panel-title\">OVERVIEW<\/h4>\n<\/div>\n<div id=\"overview-prod\" class=\"panel-collapse collapse in\" aria-expanded=\"false\">\n<div class=\"panel-body\">\n<p>Fully Automatic Random Access Bench Top Clinical Chemistry Analyser<\/p>\n<\/div>\n<\/div>\n","protected":false},"featured_media":20473,"template":"","meta":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/product\/20472"}],"collection":[{"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/product\/20472\/revisions"}],"predecessor-version":[{"id":20474,"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/product\/20472\/revisions\/20474"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/media\/20473"}],"wp:attachment":[{"href":"https:\/\/nestcorner.com\/index.php\/wp-json\/wp\/v2\/media?parent=20472"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}